January 30, 1986

To: Manufacturing and QC personel

From: Robert Briody

Subject: 15 Amp AC switch deviation for V16's and V24's

Until the CarlingSwitch AC switch becomes available (approx. 7 weeks), use
the Littlefuse switch. Since the neon lamp is integral to the switch and 
internally wired, only 4 quick disconnect terminals are present. The 
CarlingSwitch does NOT have an INTERNALLY wired lamp and thus has 6 quick
disconnect terminals. Orient and wire the Littlefuse switch as follows (Note:
this is a rear view.)