.sp 4
September 9, 1986
.sp 4
.nf
Jeff Kelly
Power General
152 Will Dr.
Canton, MA  02021
.fi
.sp 2
Dear Mr. Kelly;
.sp 1
.PP
I received the two Power General P/N 4200-3 power supplies with the modified
-5 VDC output. Our testing revealed an error on our part. The 1.5 Amp output
originally specified for the -5 VDC output should actually be 2.0 Amps. This 
mistake was due to an error in measurement of our graphics board's current
requirements. The power supply functions flawlessly in all other respects.
.PP
If this power supply problem can be solved in a timely fashion, I estimate
that Integrated Solutions would be placing an order for the modified supply
in 4 to 6 weeks. I'm looking forward to your response.
.sp 4
.nf
Sincerely,
.sp 4
Robert Briody
Design Engineer